Page tree
Skip to end of metadata
Go to start of metadata

Sometimes CREATE SEQUENCE may not work in Oracle data base when the replication is run. In such cases sync_id will not be created. Hence an error will generate after running replication.

Solution:

This issue can be resolved by executing the following query in Oracle data base before running the replication. This query will create sequence hence create sync_id.

CREATE SEQUENCE  "DBSYNC"."SYNCH_SEQ"  MINVALUE 1 MAXVALUE 9999999999999999999999999999 INCREMENT BY 1 START WITH 1 CACHE 20 NOORDER  NOCYCLE ;

CREATE SEQUENCE  "DBSYNC"."NEXTVAL"  MINVALUE 1 MAXVALUE 9999999999999999999999999999 INCREMENT BY 1 START WITH 1 CACHE 20 NOORDER  NOCYCLE ;